LOCATE A DISTRIBUTOR FOR THIS PRODUCT
Please select a province




Littelfuse

    Class CC




Littelfuse

All Manufacturers > Littelfuse > Class CC > CCMR - Time Delay

Series: CCMR
Direct cross for: LP_CC,LPCC,ATDR,EDCC

       
Technology:: Leaded and Cartridge
CCMR Series - Class CC Dual Element Time Delay Fuse for Short-Circuit Protection of Motor Branch-circuits



For space-saving protection of motor circuits up to 40 HP**, we recommend Littelfuse POWR-PRO? CCMR series fuses.

  • These fuses are the only true dual-element time-delay CC fuses specifically engineered for motor branch circuit protection.
  • They provide Type II protection (no damage) to both NEMA-rated and the more sensitive IEC (International Electromechanical Commission) type motor circuit components.
  • CCMR series fuses are now available in larger sizes — from 35 to 60 amperes! No other 600V fuse is available with this current carrying capacity in a package this small.
  • Compared to other UL Listed fuses, Class CC fuses are the most current limiting, rating for rating.
  • Because they are physically compact, they provide this superior protection in a fraction of the space required by other fuse classes.
For example, when 600V three-pole, 30 ampere Class R fuse blocks are replaced by Littelfuse Class CC fuse blocks, panel-mounting space is reduced approximately 70%. This is especially important when a panel contains many fuses to protect multiple circuit components.

Applications:
Three types of Class CC Fuses, specifically designed to protect different types of components:
  1. Motor protection – CCMR series; dual-element, time-delay fuses specifically designed to protect motor circuits up to 40 HP**.
  2. Small transformer protection (control power transformers) – KLDR series, time-delay fuses designed to withstand the high magnetizing inrush of transformers.
  3. General purpose protection of equipment requiring fast overload protection – KLKR series, fast-acting fuses used for protection of equipment containing solid-state devices or other electronic components requiring fast response on overloads.
Safety:
  • 200,000 A.I.R. — Reliable interruption of all overcurrents up to 200,000 amperes.
  • Extremely current limiting — Reduces damage caused by heating and magnetic effects of short-circuit currents…stops damaging short-circuit faster than any mechanical protective device.
Space Saving:
  • Class CC fuses are the smallest 600V, 200,000 A.I.R. fuses approved for branch circuit protection.
Economical
  • Current limiting design often permits use of readily available, less costly equipment.
Datasheets
Class CC - Series Data Sheet
ClassCC.pdf (180 K)

Last Updated: January 28, 2005 11:31am

TC Curve
CCMR Series Time Curve Data
CCMR.tc.pdf (14 K)